Addition to the toilet waste, the Saniplus will also discharge gray water from a variety of other sanitary fixtures such as: a sink, a bathtub, a shower and a urinal when adding a bathtub or shower, a base will have to be constructed this base should be made out of a 2 in. x 6 in. (minimum) or 2 in. x 8 in. (recommended) on edge, to allow for the installation of a P-trap and the required 1/4 in. per foot gravity flow towards the pump unit
Wastewater from other sanitary fixtures is discharged into the Saniplus via two 2 in. inlets on either side of the housing either one or both inlets can be used as required the discharge elbow on top of the Saniplus can be turned either to the left, to the right, or towards the back, depending on the discharge installation a non-return valve, which comes already assembled on the discharge elbow, prevents back flow into the unit
Unit has been designed with a vent connection on the lid all plumbing codes require connection to a vent system please note that the vent system should be a two-way air vent the use of mechanical vents, air admittance valves or similar devices are not permitted as these are considered one-way air vent systems it is also highly recommended for the macerator/pump to be connected to a Ground Fault Interrupter (GFI) circuit
Design of this model consists of vibration absorbers which enable the reduction of operating sound by reducing the transmitted sounds from any location where such resonance transmission could occur this new design reduces the operating sound of this pump by 10dB